Please log in to determine if you are eligible to purchase PT Programs.
CORRECTED RESULTS - QT16
QT16

The CAP developed this monitor in recognition of the importance of timely detection and correction of erroneous laboratory results. Accuracy in laboratory results is critical to the effectiveness of a physician’s plan of care for a patient. An erroneous result can delay or alter patient treatment; therefore, detection of erroneous results should be a priority in every laboratory and should be monitored as a key quality indicator. Help measure your compliance with CLIA 493.1299, Postanalytic Systems Quality Assessment, and help meet CAP Laboratory Accreditation Program Checklist statements GEN.20136, 41310, 41312, and The Joint Commission standard 02.12.01, Elements of Performance 9 and 10, with this monitor.


Objective

Monitor the number of corrected test results within individual institutions and compare performance with that of all institutions and those institutions similar to yours.

Data Collection

On a monthly basis, participants will monitor the number of corrected test results and the total number of billable tests for that month. Include test results for all patients in all care settings with the following exclusions: anatomic pathology tests, narrative physician-interpreted tests (eg, bone marrow biopsies and peripheral smear reports), and point-of-care tests.

Performance Indicator

  • Test result correction rate (per 10,000 billable tests)

Shipping Schedule

  • Shipment A: December 4, 2023
  • Shipment B: March 11, 2024
  • Shipment C: June 10, 2024
  • Shipment D: September 9, 2024

Additional Information

Participants in this program receive:

  • User Guide
  • Templates and instructions for data collection
  • Quarterly reports that include fingerprint clusters, customer-defined groups, and all institution comparisons
  • Peer directory

Quality Management Tools activities meet the American Board of Pathology MOC Part IV Practice Performance Assessment requirements.

For Comprehensive Collection of Tools, see Quality Management Tools.


 
Select Q-PROBES and Q-TRACKS studies to support your quality improvement initiatives.
Preanalytic
Analytic
Postanalytic
Anatomic Pathology
Clinical Pathology
Turnaround Time
Patient Safety
Microbiology
Transfusion Medicine
Chemistry/ Hematology
Customer Satisfaction
Q-PROBES
Non-Physician Care Team Satisfaction With Clinical Laboratory Services (QP231)
Technical Competency Assessment of Body Fluid Review (QPB10)
Technical Competency Assessment of Peripheral Blood Smears (QPC10/QPC25)
Technical Competency Assessment of Gram Stains (QPD10/QPD25)
Q-TRACKS
Patient Identification Accuracy (QT1)
Blood Culture Contamination (QT2)
Laboratory Specimen Acceptability (QT3)
In-Date Blood Product Wastage (QT4)
Gynecologic Cytology Outcomes: Biopsy Correlation Performance (QT5)
Satisfaction with Outpatient Specimen Collection (QT7)
Stat Test Turnaround Time Outliers (QT8)
Critical Values Reporting (QT10)
Troponin Turnaround Times (QT15)
Corrected Results (QT16)
Outpatient Order Entry Errors (QT17)

*The CAP requires accredited laboratories to have a quality management plan that covers all areas of the laboratory and includes benchmarking key measures of laboratory performance (GEN.13806, GEN.20316, COM.04000). The Joint Commission requires accredited hospitals to regularly collect and analyze performance data (PI.01.01.01, PI.02.01.01). CLIA requires laboratories to monitor, assess, and correct problems identified in preanalytic, analytic, and postanalytic systems (§493.1249, §493.1289, §493.1299).