Please log in to determine if you are eligible to purchase PT Programs.
QUALITY CROSS CHECK-HEMATOLOGY - FH4Q
FH4Q
Analyte/Procedure Challenges per Shipment Number of Shipments
Hematocrit 3 Two shipments per year
Hemoglobin 3
Large unstained cells (LUC) 3
MCV, MCH, and MCHC 3
MPV 3
Platelet count 3
RDW 3
Red blood cell count 3
WBC differential 3
White blood cell count 3

This program does not meet regulatory requirements for proficiency testing. See the FH series.


Additional Information

Quality Cross Check is a convenient solution to monitor instrument performance and assess comparability across multiple instruments in your laboratory and to identify potential issues before they affect patient results. These programs are designed to complement your existing proficiency testing (PT) and maintain compliance with the CMS directive regarding PT on multiple instruments.

How It Works:

  • Receive three challenges in each of two mailings a year.
  • Report up to three instruments for each challenge.
  • Receive a custom report package that includes peer group comparison and instrument comparability statistics for each reported analyte.

Program Information

  • Three 2.5-mL whole blood specimens in vials with pierceable caps
  • Report up to three instruments.
  • For method compatibility, see instrument matrix
  • Conventional and International System of Units (SI) reporting offered

Shipping Schedule

  • Shipment A: February 19
  • Shipment B: July 15

Instrument FH and FHQ Series
  FH1 FH2 FH3 / FH3Q FH4 / FH4Q FH9 / FH9Q FH10 FH13 / FH13Q FH16 / FH3Q FH17
Abbott Cell-Dyn® 1200, 1400, 1600, 1700, 1800, EmeraldTM                
Horiba ABX 9000+, 9018+, 9020+
Sysmex K-series, K-1000/KCP-1, KX-21/21N, pocH-100i, XP-series
CDS/Medonic M-series
Coulter® AcTTM, Diff/Diff 2 MD 2/8/10/16, ONYXTM, S880, S-plus V, ST, STKR, T-series
Drew Scientific DC-18, I-1800, DREW3, EXCELL 10/16/18
Horiba ABX Micros, Mindray BC-2800, 3000/3200 series
Mindray BC-2800, 3000/3200 series, BC-6000/BC-6200/BC-6800/BC-6800 Plus
Siemens ADVIA® 360
Abbott Cell-Dyn 3000, 3500, 3700, 4000, Emerald 22/AL, RubyTM, SapphireTM
Biosystems SA HA3/HA5
Drew Scientific EXCELL 22, 2280
Orphee Mythic 18, 22 AL, 22 OT, 60
Siemens ADVIA 560
Siemens ADVIA 120, 120 w/SP1, 2120
Abbott Alinity hq, Sysmex XE-2100, XE-2100C, XE-2100D, XE-2100DC, XE-2100D/L (Blood Center), XE-2100L, XE-5000, XN-series (includes RL App), XN-L series, XS-500i, XS-800i, XS-1000i, XS-1000i-AL, XS-1000iC, XT-1800i, XT-2000i, XT-4000i
Coulter AcT 5 diff (AL, CP, OV)
DIRUI BF series
Horiba ABX Pentra 60, 80, 120, Pentra DF Nexus
Coulter LH 750, LH 755, LH 780, LH 785, UniCel DxH series (except DxH 500 series)
Coulter DxH 500 series, Horiba Yumizen H500/550, H1500/2500
Horiba Yumizen H500/550, H1500/2500
Mindray BC-700, BC-720, BC-760, BC-6000, BC-6000 Plus, BC-6100, BC-6100 Plus, BC-6200, BC-6200 Plus, BC-6600, BC 6600 Plus, BC-6700, BC-6800, BC-6800 Plus, BC-7500





Customers Who Bought This Item Also Bought
HEMATOLOGY BENCHTOP REFERENCE GUIDE
VIEW DETAILS >
Color Atlas Of Hematology: An Illustrated Field Guide Based On Proficiency Testing, 2nd Edition
VIEW DETAILS >
HEMATOLOGY AUTOMATED DIFFERENTIAL SERIES
VIEW DETAILS >
HEMATOLOGY CVL
VIEW DETAILS >